SUMMARY
While the dynamics of running arthropods have been modeled as a spring-mass system, no such structures have been discovered that store and return energy during bouncing. The hindleg of the cockroach Blaberus discoidalis is a good candidate for a passive, vertical leg spring because its vertically oriented joint axes of rotation limit the possibility of active movements and contributions of muscle properties. We oscillated passive legs while measuring force to determine the leg's dynamic, mechanical properties. The relative dimensionless stiffness of an individual cockroach leg was equal to that estimated for a single leg of a biped or quadruped. Leg resilience ranged from 60 to 75%, affording the possibility that the leg could function as a spring to store and return the mechanical energy required to lift and accelerate the center of mass. Because hysteresis was independent of oscillation frequency,we rejected the use of a Voigt model – a simple spring in parallel with a viscous damper. A hysteretic damping model fit the cockroach leg force–displacement data over a wide range of frequencies and displacement using just two parameters. Rather than simply acting as a spring to minimize energy, we hypothesize that legs must manage both energy storage and absorption for rapid running to be most effective.
Introduction
Running by legged arthropods is well modeled as a spring-mass system in both the sagittal and horizontal plane(Blickhan and Full, 1987; Full and Tu, 1990; Full and Tu, 1991; Schmitt and Holmes, 2000a; Schmitt and Holmes, 2000b). Three or four legs sum to function as a single, virtual leg-spring, appearing to bounce the animal's center of mass forward(Blickhan and Full, 1993). However, direct evidence of spring-like function in arthropod legs during rapid running is lacking. Arthropods rely on energy storage and power amplification by elastic structures during flight, sound generation, jumping and predatory strikes (for a review, see Gronenberg, 1996). Insect flight might be impossible in the absence of elastic structures that reside in the thoracic cuticle, resilin pads and the flight muscles themselves(Ellington, 1984; Weisfogh, 1973). Jumping locusts store energy in passive skeletal elements that include the bending of their tibial leg segment, the compression of elastomeric structures and the stretching of extensor tendons or apodemes(Bennet-Clark, 1975; Katz and Gosline, 1992). The legs of arthropods, such as locusts and spiders, have been shown to be highly resilient, storing and returning as much as 90% of the energy invested to deflect them (Blickhan, 1986; Katz and Gosline, 1992; Sensenig and Shultz, 2003). Dynamic oscillations of legs within the range of displacements and frequencies observed during running are needed to search for spring-like behavior.
In the present study, we determine the passive mechanical properties of the cockroach leg and examine the role they might play in managing energy during running. The deathhead cockroach, Blaberus discoidalis, has the dynamics of a spring-mass system during running, but the presence and location of spring-like elements remain a mystery(Blickhan and Full, 1993; Full and Tu, 1990). We selected cockroaches to simplify our search, because their legs have more vertically oriented joint axes such that a vertical displacement of a leg results in passive deflection of the exoskeleton rather than rotation of flexible joints under muscle control. Since the leg cuticle in other terrestrial insects is more than 90% resilient(Blickhan, 1986; Katz and Gosline, 1992; Sensenig and Shultz, 2003), we hypothesized that during running the leg acts as an energy-storing spring. Rapidly running cockroaches, cycling their legs at high frequencies, have little time to react to perturbations and yet these insects appear to absorb energy effectively and self-stabilize when perturbed. Jindrich and Full found that these cockroaches do not even require step transitions to recover from lateral perturbations caused by force impulses as high as 80% of forward running momentum (Jindrich and Full,2002). Given their remarkable stability, we also hypothesize that legs act as energy-absorbing dampers, passively removing energy from perturbations, potentially simplifying control. By directly oscillating legs as we measured force, we tested whether an arthropod leg during running operates as a viscoelastic structure represented by a simple spring in parallel with a viscous damper – often referred to as a Voigt model.
Materials and methods
Animals
Adult deathhead cockroaches (Blaberus discoidalis L.) of both sexes were obtained from Carolina Biological Supply (Gladstone, OR, USA) and used for all experiments (3.08±0.73 g, N=12 animals). Animals were housed in large plastic containers and fed dried dog food and water ad libitum. All cockroaches were euthanized immediately prior to an experiment in a 237-ml jar saturated with ethyl acetate vapor. Experiments were performed at room temperature (24°C).
Dynamic oscillations
Dynamic oscillations of the meta-thoracic limbs of cockroaches were performed to quantify their viscoelastic properties. Oscillations were performed on legs using two distinct preparations: one in which the body–coxa joint was rigidly fixed and another where the body–coxa joint was free to rotate. This was done in an attempt to bound the possible material properties of the leg from zero muscle activation (free-coxa) to infinitely stiff muscles (fixed-coxa). Since the joint axes of the more distal joints are oriented nearly vertical (Fig. 1A,B), muscle activation should have minimal effect on material properties during vertical oscillations.
In the fixed-coxa preparation (Fig. 1C), the ablated, metathoracic limb was affixed using epoxy resin to 0.95 cm-thick Plexiglas such that the trochanter, femur and tibia were free to rotate. Legs (N=7 animals, n=13 legs) were cut as proximally as possible in the unsclerotized region of the body–coxa joint using fine dissecting scissors and the tarsus was removed. No hemolymph loss was observed from either end of the leg. One end of a stainless steel pin(0.33 mm o.d.) was inserted into the distal tip of the tibia and secured with cyanoacrylate. The other end of the pin was attached to the arm of a servo-motor (300B-LR; Aurora Scientific, Aurora, ON, Canada) using dental compound (Kerr; Orange, CA, USA). The servo-motor input a time-varying displacement while simultaneously measuring force with a resolution of 0.25 mN.
In the free-coxa preparation (Fig. 1D), the euthanized cockroach was rigidly tethered to a bronze rod by the metanotum. The meta-thoracic limb (N=5 animals, n=10 legs) was attached to the arm of a servo-motor in the same manner as the fixed preparation. In this preparation, the body–coxa joint and all leg joints distal to it were free to rotate.
In both preparations, dynamic tests of the limb were performed in the dorso-ventral direction with sinusoidal displacements ranging from 0.1 to 1.0 mm at frequencies ranging from 0.05 to 60 Hz. The tibia and the pin connecting the limb to the servo-motor made a 110° angle relative to one another(Fig. 1C,D). The leg was oscillated dorso-ventrally to simulate the position of the legs and the effect of the body mass pushing down during the mid-stance of running. It also simulates a vertical perturbation of the leg during mid-swing. The displacements were chosen because the center of mass (COM) has been calculated to deflect vertically 0.3 mm during a stride(Full and Tu, 1990). The angle was chosen because the meta-thoracic body–coxa joint is held at a nearly constant 20° angle during the stance phase of running(Kram et al., 1997).
Controls
Preparation
To gain the most secure and repeatable connection, the lever was attached to the most distal portion of the tibia. Leaving the tarsus intact resulted in a 30 min delay between euthanasia and testing because of the need for the adhesive to dry. Removal of the tarsus decreased preparation to 5 min. For all data presented in this study, the tarsus of each tested leg was removed(Fig. 1C,D). As a control, we performed tests 30 min post-mortem without removing the tarsus. Results from legs with tarsi were not significantly different from legs without tarsi (P>0.05), where tests began 5 min post-mortem. Leg properties remained unchanged for at least 3 h in both the fixed-coxa and free-coxa preparations. Jensen and Weis-Fogh observed water loss in ablated locust tibia at a rate of 1% per hour, but `48 h of storage without protection against evaporation had no appreciable effect upon the stress–strain relationship' of cuticle ribbons(Jensen and Weis-Fogh, 1962). Therefore, if desiccation has an effect on material properties, it either occurs entirely in the first 5 min or requires more than 3 h to be measured.
Muscle activity
To test if post-mortem reflex muscle activity was playing a role in the legs of euthanized cockroaches, electromyograms were recorded from three coxa depressor muscles (177c, 177d and 179), one coxa levator (182c),one tibia extensor (194a) and one tibia flexor (185) (following Watson and Ritzmann, 1998). No muscle activity was observed in any of the six muscles examined.
Hemolymph pressure
While we did not measure internal pressure directly, it did not affect the mechanical properties of the leg. Removing the tarsus or cutting a hole in the mesonotum, both of which should eliminate internal leg pressure, had no significant effect. Moreover, hemolymph pressure in the cockroach Periplaneta americana has been shown to be only –0.005 atm(101.325 kPa atm–1)(Davey and Treherne, 1964). While large fluctuations in hemolymph pressure have been observed during digging movements in newly emerged adult flies (from 0.05 atm at rest to as high as 0.15 atm), `running merely produces a slight irregularity of the(pressure) traces' (Cottrell,1962). To test for pressure effects, we compared living cockroaches with euthanized cockroaches and found no significant difference. It is possible that the thorax depressurizes post-mortem, but the leg properties of living, recently actively struggling cockroaches were not different from those of living, calmly standing cockroaches.
Data acquisition and parameter calculations
Displacement and force signals from the servo-motor were digitized (board AT-MIO-16E-1; National Instruments, Austin, TX, USA) at sampling rates dependent on oscillation frequency and stored to the hard disk of a personal computer (Berta, Transduction Ltd, Mississauga, ON, Canada) running analysis software (MATLAB, The MathWorks, Natick, MA, USA).
Prior to any calculations, raw force and displacement signals were filtered using a 4th-order low-pass Butterworth filter at one-quarter the peak cutoff frequency for each trial. Peak cutoff frequency varied from trial to trial because oscillation frequency and sampling rate varied. For example, when sampling at 4000 Hz, the peak cutoff frequency to prevent aliasing is 2000 Hz,and one-quarter the peak cutoff frequency is 500 Hz. The maximum allowed frequency of the filter was never less than eight times the oscillation frequency. Visual inspection of the pre- and post-filtered power spectra did not reveal any noticeable structures outside the allowed frequency band. At low frequencies, spectral artifacts due to the intermittent movement of the lever arm were observed and removed by this filter. All calculations were performed using a mathematics program (MATLAB).
Impedance
Phase shift
Resilience
Modeling leg properties
Viscous damping model – Voigt model
Hysteretic damping model
Statistical analysis
Both the left and right limbs were used from each animal tested. One-way analyses of variance (ANCOVAs) (separate slopes model) were performed to examine the relationship of the mechanical properties to the oscillation frequency. Data for the ANCOVAs were grouped by coxa preparation, amplitude of imposed displacement and, initially, left or right leg. Visual inspection showed that there was a break in the data at 25 Hz, with most properties increasing as a function of frequency up until 25 Hz and then remaining constant or decreasing as frequency increased further. Therefore, ANCOVAs were performed on two separate frequency ranges, 0.05–25 Hz and 25–60 Hz. Reported intercepts correspond to a frequency of 1 Hz because the ANCOVAs were performed on log10-transformed frequencies. All tests were performed using statistics software packages (JMP; SAS Institute, Cary, NC,USA; Statistics toolbox; The MathWorks). Unless otherwise stated, all reported values are means ± standard errors (fixed-coxa, n=13 legs;free-coxa, n=10 legs).
Results
For each leg preparation, the left and right hindlimbs were tested with 85 treatments each for a total of 12 animals, 23 legs and 1955 tests. Tukey-Kramer post-hoc tests revealed that there was no significant difference in the mechanical properties of the left and right legs. Therefore,data from the left and right legs of each preparation were pooled for data analysis. Visual inspection revealed that the variance of the data for each individual was similar, so equal variances were assumed.
Induced forces
For all but the smallest amplitude displacement (0.1 mm), the resulting hysteresis loops were nonlinear (Fig. 2). The effect of increasing oscillation frequency on absolute forces was marginally significant, with induced force increasing less than 1 mN in most cases per decade increase of frequency from 0.05 to 25 Hz. Induced forces remained constant at frequencies from 25 to 60 Hz. Frequency did not have an effect on the shape of the hysteresis loops(Fig. 2). As displacement amplitude increased, the induced forces increased (ANCOVA with Tukey-Kramer honestly significant difference post-hoc test) and the loops became increasingly non-linear (Fig. 2C,D). At the same oscillation frequency and amplitude, induced forces were 50% (0.1 mm amplitude) to 65% (1.0 mm amplitude) lower (ANCOVA,Tukey-Kramer) for a leg with a freely rotating coxa when compared with a rigidly fixed leg. The percent difference between the two preparations was not a constant because the slopes of the regressions were significantly lower(ANCOVA, Tukey-Kramer) for the free-coxa preparation.
Average peak force ranged from 2.4±0.1 mN (0.1 mm at 0.25 Hz) to 21.9±2.2 mN (1.0 mm at 40 Hz) in the fixed-coxa leg. Forces of the free leg ranged from 1.2±0.1 mN (0.1 mm at 0.25 Hz) to 7.8±0.9 mN(1.0 mm at 40 Hz). By comparison, the vertical ground reaction force produced by the hindlimb during running is 11.9±0.9 mN(Full et al., 1991).
Impedance
Fixed-coxa leg impedance increased significantly as oscillation frequency increased from 0.05 to 25 Hz (Table 1) and declined slightly from 25 to 60 Hz(Fig. 3A). Increases in free-coxa leg impedance as a function of frequency(Fig. 3B) were significantly less pronounced (ANCOVA, Tukey-Kramer post-hoc test on slopes) than in the fixed-coxa preparation. For fixed-coxa legs, impedance was significantly greater for 0.1 mm oscillations than for the larger amplitudes(ANCOVA, Tukey-Kramer), with no significant difference for oscillations ranging from 0.3 to 1.0 mm. Free-coxa legs also had significantly higher impedance at low amplitude, but the intercepts continued to decrease as amplitude increased (Table 1). At the same oscillation frequency and amplitude, impedance was 50% (0.1 mm amplitude) to 65% (1.0 mm amplitude) lower (ANCOVA, Tukey-Kramer on intercepts) for a leg with a freely rotating coxa when compared with a rigidly fixed leg.
. | . | Fixed coxa . | . | . | Free coxa . | . | . | ||||
---|---|---|---|---|---|---|---|---|---|---|---|
Variable . | Source . | d.f. . | F . | P . | d.f. . | F . | P . | ||||
Impedance | Amplitude | 4 | 4355.4 | <0.0001 | 4 | 2874.1 | <0.0001 | ||||
Frequency | 1 | 6243.2 | <0.0001 | 1 | 1794.0 | <0.0001 | |||||
Amplitude × frequency | 4 | 163.8 | <0.0001 | 4 | 83.6 | <0.0001 | |||||
Error | 50 | 50 | |||||||||
Phase shift (δ) | Amplitude | 4 | 9.9 | <0.0001 | 4 | 4.2 | 0.0051 | ||||
Frequency | 1 | 11.3 | 0.0015 | 1 | 17.2 | 0.0001 | |||||
Amplitude × frequency | 4 | 0.6 | 0.6803 | 4 | 0.2 | 0.9210 | |||||
Error | 50 | 50 | |||||||||
Hysteretic stiffness (k) | Amplitude | 4 | 667.4 | <0.0001 | 4 | 218.1 | <0.0001 | ||||
Frequency | 1 | 1191.3 | <0.0001 | 1 | 291.3 | <0.0001 | |||||
Amplitude × frequency | 4 | 25.9 | <0.0001 | 4 | 2.1 | 0.0958 | |||||
Error | 50 | 50 | |||||||||
Damping factor (γ) | Amplitude | 4 | 3.0 | 0.0295 | 4 | 1.7 | 0.1725 | ||||
Frequency | 1 | 2.8 | 0.0998 | 1 | 0.1 | 0.7130 | |||||
Amplitude × frequency | 4 | 0.1 | 0.9683 | 4 | 0.9 | 0.4605 | |||||
Error | 45 | 45 |
. | . | Fixed coxa . | . | . | Free coxa . | . | . | ||||
---|---|---|---|---|---|---|---|---|---|---|---|
Variable . | Source . | d.f. . | F . | P . | d.f. . | F . | P . | ||||
Impedance | Amplitude | 4 | 4355.4 | <0.0001 | 4 | 2874.1 | <0.0001 | ||||
Frequency | 1 | 6243.2 | <0.0001 | 1 | 1794.0 | <0.0001 | |||||
Amplitude × frequency | 4 | 163.8 | <0.0001 | 4 | 83.6 | <0.0001 | |||||
Error | 50 | 50 | |||||||||
Phase shift (δ) | Amplitude | 4 | 9.9 | <0.0001 | 4 | 4.2 | 0.0051 | ||||
Frequency | 1 | 11.3 | 0.0015 | 1 | 17.2 | 0.0001 | |||||
Amplitude × frequency | 4 | 0.6 | 0.6803 | 4 | 0.2 | 0.9210 | |||||
Error | 50 | 50 | |||||||||
Hysteretic stiffness (k) | Amplitude | 4 | 667.4 | <0.0001 | 4 | 218.1 | <0.0001 | ||||
Frequency | 1 | 1191.3 | <0.0001 | 1 | 291.3 | <0.0001 | |||||
Amplitude × frequency | 4 | 25.9 | <0.0001 | 4 | 2.1 | 0.0958 | |||||
Error | 50 | 50 | |||||||||
Damping factor (γ) | Amplitude | 4 | 3.0 | 0.0295 | 4 | 1.7 | 0.1725 | ||||
Frequency | 1 | 2.8 | 0.0998 | 1 | 0.1 | 0.7130 | |||||
Amplitude × frequency | 4 | 0.1 | 0.9683 | 4 | 0.9 | 0.4605 | |||||
Error | 45 | 45 |
Frequency values were log10-transformed prior to statistical analysis.
Phase shift
For both fixed- and free-coxa legs, the induced force reached a maximum prior to the maximum displacement, resulting in a phase shift, δ,between the force and displacement signals(Fig. 4A,B). There was no significant relationship between tan(δ) and oscillation frequency(ANCOVA, Tukey-Kramer). Within the fixed- and free-coxa treatments, only the 0.1 mm amplitude oscillations had significantly different intercepts from the larger (0.3–1.0 mm) amplitude oscillations(Table 1; Fig. 4C,D). At the same oscillation frequency and amplitude, tan(δ) was the same at 0.1 mm amplitudes to 40% larger at 1.0 mm amplitudes (ANCOVA, Tukey-Kramer) in the free-coxa preparation compared with the fixed-coxa preparation.
Energy storage, return and lost
The work performed during each loading (Eload) and unloading cycle (Eunload) (see Fig. 4B) increased significantly, but only by a small percentage, with oscillation frequency from 0.05 to 25 Hz (Table 2; Fig. 5A,B). For both fixed- and free-coxa legs, energy expended per cycle increased significantly as oscillation amplitude increased (ANCOVA, Tukey-Kramer on intercepts). At the same oscillation frequency and amplitude, the loading and unloading(Table 2) energies in the free-coxa leg were 45% (0.1 mm amplitude) to 70% (1.0 mm amplitude) less(ANCOVA, Tukey-Kramer on intercepts) than the loading energies in the fixed-coxa leg.
. | . | Fixed coxa . | . | . | Free coxa . | . | . | ||||
---|---|---|---|---|---|---|---|---|---|---|---|
Variable . | Source . | d.f. . | F . | P . | d.f. . | F . | P . | ||||
Loading energy | Amplitude | 4 | 21 915.5 | <0.0001 | 4 | 20 250.1 | <0.0001 | ||||
Frequency | 1 | 145.9 | <0.0001 | 1 | 383.1 | <0.0001 | |||||
Amplitude × frequency | 4 | 20.4 | <0.0001 | 4 | 67.7 | <0.0001 | |||||
Error | 50 | 50 | |||||||||
Unloading energy | Amplitude | 4 | 17 437.5 | <0.0001 | 4 | 3770.5 | <0.0001 | ||||
Frequency | 1 | 341.0 | <0.0001 | 1 | 58.8 | <0.0001 | |||||
Amplitude × frequency | 4 | 67.6 | <0.0001 | 4 | 8.8 | <0.0001 | |||||
Error | 50 | 50 | |||||||||
Energy lost | Amplitude | 4 | 1555.8 | <0.0001 | 4 | 1523.7 | <0.0001 | ||||
Frequency | 1 | 15.1 | <0.0001 | 1 | 39.0 | <0.0001 | |||||
Amplitude × frequency | 4 | 9.1 | <0.0001 | 4 | 8.9 | <0.0001 | |||||
Error | 50 | 50 | |||||||||
Resilience | Amplitude | 4 | 15.2 | <0.0001 | 4 | 3.5 | <0.0001 | ||||
Frequency | 1 | 80.9 | <0.0001 | 1 | 0.4 | <0.0001 | |||||
Amplitude × frequency | 4 | 1.3 | 0.2993 | 4 | 0.6 | 0.6847 | |||||
Error | 50 | 50 |
. | . | Fixed coxa . | . | . | Free coxa . | . | . | ||||
---|---|---|---|---|---|---|---|---|---|---|---|
Variable . | Source . | d.f. . | F . | P . | d.f. . | F . | P . | ||||
Loading energy | Amplitude | 4 | 21 915.5 | <0.0001 | 4 | 20 250.1 | <0.0001 | ||||
Frequency | 1 | 145.9 | <0.0001 | 1 | 383.1 | <0.0001 | |||||
Amplitude × frequency | 4 | 20.4 | <0.0001 | 4 | 67.7 | <0.0001 | |||||
Error | 50 | 50 | |||||||||
Unloading energy | Amplitude | 4 | 17 437.5 | <0.0001 | 4 | 3770.5 | <0.0001 | ||||
Frequency | 1 | 341.0 | <0.0001 | 1 | 58.8 | <0.0001 | |||||
Amplitude × frequency | 4 | 67.6 | <0.0001 | 4 | 8.8 | <0.0001 | |||||
Error | 50 | 50 | |||||||||
Energy lost | Amplitude | 4 | 1555.8 | <0.0001 | 4 | 1523.7 | <0.0001 | ||||
Frequency | 1 | 15.1 | <0.0001 | 1 | 39.0 | <0.0001 | |||||
Amplitude × frequency | 4 | 9.1 | <0.0001 | 4 | 8.9 | <0.0001 | |||||
Error | 50 | 50 | |||||||||
Resilience | Amplitude | 4 | 15.2 | <0.0001 | 4 | 3.5 | <0.0001 | ||||
Frequency | 1 | 80.9 | <0.0001 | 1 | 0.4 | <0.0001 | |||||
Amplitude × frequency | 4 | 1.3 | 0.2993 | 4 | 0.6 | 0.6847 | |||||
Error | 50 | 50 |
Frequency values were log10-transformed prior to statistical analysis.
For legs with a fixed coxa, the energy lost (Elost)during each cycle actually decreased as oscillation frequency increased from 0.05 to 25 Hz (Table 2; Fig. 5E). However, this decrease was only statistically significant for 1.0 mm amplitude oscillations. For free-coxa legs, energy lost increased significantly, but only by a small percentage, for 0.5–1.0 mm amplitudes, as oscillation frequency increased (Fig. 5F). For both leg preparations, energy lost per cycle increased significantly as oscillation amplitude increased (ANCOVA, Tukey-Kramer on intercepts). At the same oscillation frequency and amplitude, the energy lost in the free-coxa leg was 50% (0.1 mm amplitude) to 25% (1.0 mm amplitude) less (ANCOVA, Tukey-Kramer on intercepts) than the energy lost in the fixed-coxa leg.
Resilience
For both the fixed- and free-coxa preparations, resilience did not significantly increase with frequency, except at the largest (1.0 mm)amplitude (Table 2; Fig. 6A,B). In both preparations, the statistically significant slopes were small, ranging from 0.02 to 0.03. Resilience increased less than 3% per decade increase in oscillation frequency. The free-coxa leg was significantly less resilient than the fixed-coxa leg (ANCOVA, Tukey-Kramer on intercepts), averaging 71.7±0.6% for the fixed leg and 61.9±0.7% for the free leg(Fig. 6A,B).
Viscous damping model – Voigt model
The stiffness and damping parameters resulting from fitting the Voigt model to the data depend on both the frequency and amplitude of oscillation(Fig. 7). Legs with a fixed coxa were stiffer and more damped than those with a freely rotating coxa.
Leg stiffness increased as oscillation frequency increased from 0.05 to 25 Hz (ANCOVA, Tukey-Kramer) but remained nearly constant from 25 to 60 Hz. Stiffness was significantly greater for 0.1 mm oscillations than for the larger amplitudes (ANCOVA, Tukey-Kramer) with no significant difference for oscillations ranging from 0.3 to 1.0 mm. At the same oscillation frequency and amplitude, stiffness was 50% (at 0.1 mm amplitude) to 60% (1.0 mm amplitude)lower (ANCOVA, Tukey-Kramer) for a leg with a freely rotating coxa when compared with a rigidly fixed leg (Fig. 7A,B).
The viscous damping coefficient was not constant. The coefficient decreased as both oscillation frequency and amplitude increased (ANCOVA, Tukey-Kramer; Fig. 7C,D). The damping coefficient for the free-coxa leg was 40% (at small amplitudes) to 50% (large amplitudes) smaller than the damping coefficient of the fixed-coxa leg.
Hysteretic damping model
For both the fixed- and free-coxa preparations, leg stiffness increased significantly (ANCOVA, Tukey-Kramer) as oscillation frequency increased from 0.05 to 25 Hz (Table 1; Fig. 8A,B) and continued to increase from 25 to 60 Hz. Stiffness was significantly greater for 0.1 mm oscillations than for the larger amplitudes (ANCOVA, Tukey-Kramer), with no significant difference for oscillations ranging from 0.3 to 1.0 mm. At the same oscillation frequency and amplitude, stiffness was 50% (at 0.1 mm amplitude) to 60% (1.0 mm amplitude) lower (ANCOVA, Tukey-Kramer) for a leg with a freely rotating coxa when compared with a rigidly fixed leg.
The structural damping factor of both the fixed- and free-coxa legs was independent of frequency and amplitude from 0.1 to 25 Hz(Table 1) and decreased from 40 to 60 Hz (Fig. 8C,D). The fixed-coxa leg was significantly less damped than the free-coxa leg (ANCOVA,Tukey-Kramer on intercepts), averaging 0.20±0.02 for the fixed leg and 0.28±0.02 for the free leg (Fig. 8C,D).
Hysteresis loops recreated using the stiffness and damping parameters resulting from fitting a damped spring (Eqn 11) to the data closely matched the actual data at low (0.1–0.3 mm) amplitudes(Fig. 9A). At the higher amplitude (0.5–1.0 mm) displacements, the linear lumped parameter model did not capture the nonlinearities in the leg data(Fig. 9B); however, the model's peak-to-peak displacement, force and area inside the loop were within 10% of the actual data.
Discussion
Measured properties of cockroach legs did not fit a commonly applied spring-damper model but they did fit another simple, two-parameter model that captured the frequency independence of the hysteresis. While legs could function as springs during running, the damping present led us to suggest a view that energy management as it relates to stability and control best characterizes leg function rather than energy minimization.
Impedance and stiffness
Direct measurements of leg impedance(Fig. 3) and stiffness (Figs 7A,B, 9A,B) were similar to the best estimates derived from force-platform data(Full and Tu, 1990). Blickhan and Full calculated that one leg of a cockroach contributed 5.3 N m–1 to the stiffness of the SLIP (kSLIP)(Blickhan and Full, 1993) or 15.9 N m–1 to the effective vertical stiffness[keffvert; the ratio of the peak vertical force to the peak vertical displacement of the center of mass during the stance phase(McMahon and Cheng, 1990)]. We predicted that our vertical loading regime would provide leg stiffness values that more closely matched keffvert than kSLIP. Vertical leg stiffness values measured in the present study ranged from 9 N m–1 (free-leg) to 27 N m–1 (fixed-leg) (Fig. 9A,B) for cockroaches running at their preferred stride frequency(8 Hz) and with displacement amplitudes equal to the fluctuations of their center of mass (0.3 mm).
The similarity in measured and predicted leg stiffness values has several implications. First, it suggests that the exoskeleton may be a major contributor to leg stiffness. A detailed study of the coxa–body joint muscles and perhaps the femur reductor muscle at the trochanter–femur joint (Watson et al., 2002) is needed to test this assertion further, since we could only bound their function with a fixed- and free-coxa preparation. Second, the vertical loading regime for insects appears to yield reasonable estimates of leg stiffness. This may result from the fact that the relative compression of the SLIP in hexapedal runners is only one-third that observed in bipedal runners(Blickhan and Full, 1993). Hexapedal trotters also have far lower SLIP fore-aft ground reaction forces relative to vertical forces than do bipedal runners(Blickhan and Full, 1993). Third, the present leg stiffness data support the contention that hexapeds have a very stiff SLIP. Blickhan and Full found that the relative kSLIP for hexapedal trotters, like cockroaches, was three times greater than values for bipedal runners and twice as great as quadrupedal trotters (Blickhan and Full,1993). The relative stiffness of an individual cockroach leg reported here was equal to that estimated for a single leg of a biped or quadruped, despite the fact that insects appear to bounce off a tripod of legs each step (Blickhan and Full,1993; Farley et al.,1993; Full and Tu,1990).
The relatively high leg stiffness of hexapods may reveal a different strategy for the control of running compared with large bipeds and quadrupeds. The relatively high stiffness in hexapods results in small fluctuations of the center of mass. Preventing large fluctuations of the body may allow small,sprawled-posture animals to avoid contact with the substrate. The greater,relative kSLIP in cockroaches results in higher relative frequencies that minimize falling time and increase the number of ground contacts to more quickly respond to perturbations or generate maneuvers.
Phase shift, energy and resilience
Resilience of the cockroach leg measured from cycle energies(Fig. 5) ranged from 0.6 in the free coxa to 0.75 in the fixed coxa (Fig. 6). These values are lower than that reported for isolated biological material known to participate in energy storage and return. Dynamic tensile tests of the plantaris tendon of sheep produced resilience values of 0.93 (Ker, 1981). Resilin, an elastomer involved in insect flight(Ellington, 1984; Weisfogh, 1973) and retraction of the cockroach tarsus during walking(Frazier et al., 1999; Neff et al., 2000) is 96–97% resilient (Gosline,1980). Katz and Gosline calculated that the locust tibia used in jumping was more than 90% resilient (Katz and Gosline, 1992). Leg resilience values for the cockroach in the present study (Fig. 6) were more similar to those reported for arachnid joints that lack extensor muscles. Sensenig and Schultz showed that such joints with well-developed transarticular sclerites have resilience values from 70 to 90%, with the stored energy producing large enough torques to extend the joint during running (Sensenig and Schultz, 2003).
The resilience of cockroach legs was independent of frequency at all but the largest displacements (Fig. 6A,B; Table 2). At the largest amplitude oscillations, the increase was only 6% over two orders of magnitude in frequency. A similar resilience independence has been measured in sheep tendon from 1 to 11 Hz (Ker,1981). The frequency independence of resilience in oscillating cockroach legs resulted from Eloading, Eunloading and Elost all changing little from 0.1 to over 20 Hz (Fig. 5). If cockroach legs function as a spring during locomotion, they would have the potential to return the same amount of energy at all running frequencies and speeds, all else being equal.
Calculating resilience using phase-shift (δ) equations (Eqns 6, 7; Fig. 4C,D) and the linear assumptions inherent in the complex modulus (E*) over-estimated resilience by 23%, yielding values approaching 90%(Fig. 6C). Linear models assume perfect ellipsoids for force–displacement, hysteresis loops. Force–displacement data from cockroach legs became non-linear at displacements larger than 0.3 mm (Fig. 2C,D). The phase shifts of the raw data were less than that of the model, resulting in the substantial over-estimate of resilience(Fig. 6C). Linear models should be used cautiously with non-linear biomaterials. Whenever possible, resilience should be calculated by directly measuring force and displacement and using Eqn 3.
Hysteretic damping model
Force–displacement data from cockroach leg oscillations could not be modeled by a simple spring in parallel with a viscous damper (Eqn 4). We rejected the use of a Voigt model because no constant damping coefficient could be derived. Damping coefficient, c, varied by nearly four orders of magnitude over the range of frequencies tested(Fig. 7C,D). The Voigt model assumes that hysteresis or Elost decreases as oscillation frequency increases. Hysteresis (Fig. 2) or Elost(Fig. 5E,F) for the cockroach leg were independent of frequency or showed only a weak dependence on frequency at the larger displacements.
The dynamic properties of cockroach legs measured in the present study are not unusual. Many of the mechanical properties of the cockroach leg are characteristic of the majority of soft, biological tissues. The nonlinear,force–displacement relationship and the frequency independence of hysteresis are shared by muscles, arteries, veins, skin, tendon and collagen among other biological materials (Fung,1984; Fung, 1993),as well as by human-made, rubber-based elastomers(Vincent, 1990). To better characterize the mechanical behavior of biomaterials, Fung proposed the use of the hysteretic damping model (Fung,1967) that has a long history in analyzing vibration damping in airfoils (Fung, 1956), soils(Wolf, 1985), and elastomers(Nashif et al., 1985). The hysteretic damping model is so named because it was designed to reproduce the frequency independence of hysteresis or Elost per cycle. Internal, material damping is considered dominant over viscous damping, so that damping is proportional to displacement. The model is simple and linear,possessing analytic solutions to sinusoidal, dynamic oscillations. Stiffness and damping coefficients are independent of frequency, so the behavior over a wide frequency range can be described using only two parameters. Additionally,there is little error introduced by integrating or differentiating the raw force or displacement data, since fitting the function (Eqn 11) requires only data that were directly measured.
The hysteretic damping model fits the cockroach leg force–displacement data over a wide range of frequencies and displacement using just two parameters, kh and γ(Fig. 9). Because we determined kh and γ using a least-squares method, the hysteresis loops recreated using the model coefficients captured, within 10%,the energies, resiliences and peak forces and displacements. Hysteretic leg stiffness increased significantly as oscillation frequency increased from 0.05 to 25 Hz, but only by a small percentage(Table 1; Fig. 8A,B). The structural damping factor, γ, for both the fixed- and free-coxa legs was independent of frequency and amplitude from 0.1 to 25 Hz(Table 1; Fig. 8C,D).
Legs as energy-conserving springs during running
While the dynamics of small, running arthropods from cockroaches to crabs have been modeled as a spring-mass system, no elements have been discovered that store and return energy like a SLIP(Blickhan and Full, 1993; Sensenig and Shultz, 2003). The hindleg of the cockroach B. discoidalis is a candidate for an exoskeletal spring element due to its vertically oriented joint axes, which cause vertical ground reaction forces to passively bend the leg cuticle rather than a joint under muscle control. Given the material properties of the cockroach leg from the present study, we can estimate the extent to which the leg can function as an effective energy-conserving spring.
Although our estimate of energy storage and return is similar to values for kangaroos (50%) (Alexander and Vernon,1975), wallabies (25%)(Biewener and Baudinette, 1995)and humans (50%) (Ker et al.,1987), it should be considered, at best, as a first step towards determining the spring-like function of arthropod legs for a variety of reasons. First, our estimate of energy storage and return is almost certainly too high. The actual mechanical work done is likely to be much greater because the three legs of the support tripod do positive and negative work simultaneously as they push against one another(Donelan et al., 2002). Preliminary estimates of total mechanical work by integrating the instantaneous power at each joint over time result in values far exceeding the external work of the center of mass. We suspect future estimates of energy conservation to be closer to kangaroo rats (8%)(Biewener et al., 1981) than kangaroos. Second, even though each leg of an insect generates the same magnitude of vertical ground reaction force, horizontal forces differ along with leg morphology and orientation (Full et al., 1991). Studies directly measuring SLIP function during running with natural loading of the legs need to be conducted given the encouraging results of the present study. Third, we took advantage of the hindleg's greater dependence on passive structures, but future studies of the middle and front legs will require a greater understanding of muscle–apodeme function. Our simplifying assumption that all leg pairs contribute equally to spring-like function is unlikely to be verified.
Damping, stability and energy management
By their very name, spring-mass models of legged terrestrial locomotion have been biased towards spring-like energy conservation. Yet, here we report direct measurements of energy in oscillating cockroach legs that show the possibility of substantial damping even in skeletal structures (Figs 5, 6). We must remember that while the center of mass acts as if it were a SLIP during running, the same behavior could result in the absence of elastic structures where energy is lost to damping in the first half of the step, but then added in the second half of the step by way of muscle activation(Alexander, 1988). Surprisingly, human runners still use movement patterns that resemble a spring-mass system even when they must perform extra mechanical work on sand(Lejeune et al., 1998). Moritz and Farley discovered that human legs do not behave like springs during hopping on damped surfaces, yet their center of mass follows the same bouncing trajectory as if they were on an elastic surface(Moritz and Farley, 2003). These data do not support the view that animals use bouncing gaits solely because legs are energy-conserving springs.
The primary role of arthropod legs during running may not be energy storage and return. Full and Koditschek have argued(Full and Koditschek, 1999)that energy management resulting in stable locomotion is as important as energy minimization (Alexander,1988; Cavagna et al.,1977). Ting et al. demonstrated that dynamic stability was required to explain rapid running in insects(Ting et al., 1994). Using a feed-forward, hexapod model, Kubow and Full showed that cockroach locomotion viewed in the horizontal plane could be dynamically self-stabilizing with control algorithms essentially embedded in the mechanical system(Kubow and Full, 1999). Velocity perturbations alter the translation and/or rotation of the body,thereby providing `mechanical feedback' through alterations in leg moment arms. With their simple lateral leg spring model, Schmitt and Holmes showed that passive mechanics of a spring-mass system locomoting forward by bouncing from side to side can provide asymptotic stability in body rotation and orientation following a lateral perturbation(Schmitt and Holmes, 2000a; Schmitt and Holmes, 2000b). With the addition of energy absorption, the lateral leg spring model becomes asymptotically stable with respect to velocity(Schmitt and Holmes, 2003). Estimating model parameters, such as mass, leg spring stiffness, leg angle,leg length and inertia, for the cockroach B. discoidalis reveals that animals operate at or near the stability optimum for each parameter(Schmitt et al., 2002). Spring-like center-of-mass trajectories may simplify the control of locomotion.
Finally, limbs do not only function during stance but must swing back to their anterior position to support the next step. The mechanical properties that manage energy could be critical if a leg gets perturbed when in the air. While contributing to energetic inefficiency, damping may play an important role in simplifying neural control and rejecting external perturbations. Feedback control using reflexes works best given high loop gains and little delay (Rack, 1981), but this situation is rarely seen in rapidly moving animals. Due to reflex delays during both conduction and muscle activation/force generation, the immediate response of a leg to an external perturbation, such as rough terrain or debris, may depend solely on its passive mechanical properties(Brown and Loeb, 2000; McMahon and Greene, 1979; Rack, 1981). This `zero delay, intrinsic response of a neuromuscular-skeletal system to a perturbation' that can act before reflexes has been termed a `preflex'(Brown and Loeb, 2000).
Taken together, these studies support the hypothesis that tuned musculo-skeletal structures, such as legs, must manage energy for rapid running to be most effective.
Acknowledgements
We thank Lisa Pruitt, Francisco Velero-Cuevas, Benson Tongue, Mark Cutkosky and two anonymous reviewers for making helpful comments on earlier versions of this manuscript. This work was supported by DARPA/ONR –N00014-98-1-0747, DARPA/SPAWAR N66001-03-C-8045 and NSF EF 0425878 FIBR to R.J.F. and a Department of Integrative Biology summer research grant to D.M.D.