We studied structure and function of the respiratory system in the bat Tadarida brasiliensis and compared it with those of two species of rodents, Abrothrix andinus and A. olivaceus. Tadarida brasiliensis had lower resting oxygen consumption, but higher maximum oxygen consumption and aerobic scope, than the rodents. The blood–gas barrier of the bat was thinner and its relative lung size was larger; however,alveolar surface density was similar among the three species. In consequence, T. brasiliensis has an oxygen diffusion capacity two or three times higher than that of the rodents. In Tadarida brasiliensis the characteristics of the lung were accompanied by geometrical changes in the proximal airway, such as high physical optimization as a consequence of small variations in the symmetry and the scaling ratio of the bronchial diameters. These may constitute an efficient way to save energy in respiratory mechanics and are the first report of airway adjustments to decrease entropy generation in bats.

The respiratory system is a good model for studying optimization from a functional perspective because it consists of linked structures with defined design parameters and an overall function that has a measurable upper limit,the maximum rate of oxygen consumption(O2max; Weibel, 1998). There have been several studies on the optimization of the respiratory system's airway from a physical perspective, i.e. minimum entropy production in the respiratory mechanics (Rohrer, 1915; Murray, 1926; Weibel and Gomez, 1962; Canals et al., 2002a), and recently a geometrical study of the bronchial tree(Canals et al., 2002b). The geometrical design of the airway must satisfy the twin requirements of good distribution of the inspired volume of air onto a two dimensional alveolar surface and good air conduction during respiration(Canals et al., 2004). The geometry and dimensions of branched structures that make up the airway are important factors in determining the efficiency of air distribution with minimal viscous dissipation (Mauroy et al., 2004). Large bifurcation angles in the bronchial tree can increase total lung volume, and at the same time induce the best distribution of terminal tips of the bronchial tree(Canals et al., 2004). In contrast, small bifurcation angles may be necessary to avoid turbulent flow,when breathing rate is high (Kamiya et al., 1974). When the scaling ratio γd between the diameters of the daughter branches to that of the parent branch, is lower than an optimum γ*=3√(1/2)=0.7937, the resistance of the airway increases. If the scaling ratio is larger than γ* dead space increases, requiring a larger tidal volume(Mauroy et al., 2004). The symmetry of the airway, taken as similar diameters (or lengths) of daughter branches at one bifurcation, may play an important role in the optimization of the airway. On the one hand, asymmetry may reduce the scaling ratio needed for a physical optimization of the airway γ*(Mauroy et al., 2004). On the other hand the structural asymmetry of the airway may compensate any flow asymmetry due to inertial effects in symmetrical bronchial trees(Andrade et al., 1998).

Animals with high energetic requirements have physiological and structural compromise solutions for the required energetic efficiency, environmental demands and lifestyle constraints(Schmidt-Nielsen, 1997). Because flight is one of the most energetically expensive forms of locomotion,these compromises are particularly evident in flying animals. For example,birds and bats increase oxygen consumption 10- to 20-fold from rest to flight(Bartholomew et al., 1964) and their mass-specific aerobic capacities are 2.5–3 times higher than those of non-flying mammals of the same size(Thomas, 1987). To satisfy these high oxygen demands, flying animals must optimize the structure of the respiratory tract (Maina, 2000a,b, 2002) and the cardiovascular system (Greenewalt, 1975; Johansen et al., 1987; Mathieu-Costello et al., 1992;Maina, 2000a,b).

Bat lungs are similar to those of non-flying mammals, but may be highly refined to operate at near maximum values. Maina(1998) identified the bats as having a `narrow-based high-keyed strategy'. This strategy includes: (i)larger heart and cardiac output(Jürgens et al., 1981; Canals et al., 2005a), (ii)high hematocrit, high hemoglobin concentration and high blood oxygen transport capacity (Wolk and Bogdanowics, 1985) and (iii) optimization of respiratory structural parameters (Lechner,1985; Maina, 1998, 2000a,b; Jürgens et al., 1981; Maina et al., 1991).

Little is known, however, about possible refinements or adjustments of the lungs' airways as related to high energetic requirements. Recent studies on the physical optimality of the airway of rats showed a gradual approach towards the physical optimum from proximal to distal zones, which could be explained by a transition from a central distributive zone to a physical domain along the successive bifurcations of the airway(Canals et al., 2004). Canals et al. (2004) developed a geometric pattern for the branching tree, and deduced useful relationships to estimate departures from both the physical and the geometrical optima of each bronchial bifurcation. They analyzed the bronchial tree of rabbits Oryctolagus cuniculus, rats Rattus norvegicus, a small rodent Abrothrix olivaceus and the bat Tadarida brasiliensis. They demonstrated that distances to optimum values decrease from proximal to distal zones of the bronchial tree, and that the distance to the physical optimum value is always lower than that to the geometrical optimum value.

In the present studies, we examine the structural and functional parameters that characterize the respiratory system of the bat Tadarida brasiliensis. We expected the respiratory system to respond to energetic demands as a complete system. Thus, we expected high maximum oxygen consumption alongside optimal design in both lungs and airways. To contrast the findings with those obtained using the same methodology in other animals with high energetic requirements, we compared the bat's structure with those of Abrothrix olivaceus, a common rodent of low altitude lands, and the high-Andean Abrothrix andinus.

Animal models and sample size

Tadarida brasiliensis (Molossidae) Geoffroy Saint-Hilaire 1824 is a small bat that inhabits from sea level to 1000 m. This species usually colonizes urban buildings (Mann,1978; Gantz and Martinez,2000; Canals et al.,2002c). Its diet consists of small moths and beetles caught in flight in open areas. It is a streamlined bat with high wing loading and a large aspect ratio (Iriarte-Díaz et al., 2002) that facilitates high flight speeds. This species has been reported flying at an altitude of 3000 m during migration(Gantz and Martinez, 2000). Abrothrix andinus Philippi, 1858 is a high Andean-dwelling rodent that lives in sandy or rocky areas with shrub vegetation [3500 and 4600 m above sea level (masl)]. Abrothrix olivaceus Waterhouse, 1837 is found broadly in North and Central Chile where it dwells in grasslands,bushes, open forests and stony areas from sea level to 2500 masl. We studied 20 individuals of T. brasiliensis [body mass Mb=11.3±1.1 g (mean ± 1 s.d.)], 34 individuals of A. olivaceus(Mb=26.3±6.8g) and 10 individuals of A. andinus (Mb=25.5±3.2 g), in order to study their metabolism and bronchial tree. Three individuals of each species were selected for lung microscopy and another four or five for lung volume estimations. Animals were caught during spring and summer 2003 using Sherman traps or mist nets and immediately transported to the laboratory. Metabolic trials were performed within 24 h of capture. In all structural studies, the animals were euthanized by CO2 exposure following the guidelines of the Ethical Committee of the Faculty of Sciences of the University of Chile.

Oxygen consumption

Resting and maximum metabolic rates were estimated by oxygen consumption using a modified closed-circuit automatic system, based on a manometric design of Morrison (Rosenmann and Morrison,1974). Resting metabolic rate (RMR) was measured at 30°C, in post-absorptive resting animals. Maximal metabolic rate(O2max) was measured at 5°C in a He–O2 (80–20%) atmosphere,following Rosenmann and Morrison's protocol. Metabolic scope MS was estimated as O2max–RMR. Each metabolic run was conducted for 2 h after an acclimation period of 15–30 min during the active circadian phase of each species. Body temperature was measured at the end of each measurement using an intra-rectal copper–constantan thermocouple. We measured MS, O2max and RMR of 34 individuals of A. olivaceus, 9 A. andinus and 20 T. brasiliensis. Comparisons between species were analyzed with a one-way analysis of variance (ANOVA) followed by Tukey's multiple range tests.

Pulmonary structure

We removed the lungs of three individuals of each species(Mb=11.3±0.5 g, 26.3±2.0 g and 25.5±1.9 g for T. brasiliensis, A. olivaceus and A. andinus, respectively) and measured the thickness of the blood–gas barrier and the alveolar surface. We also estimated the lung's volume using the radiographic method(Canals et al., 2005b) in four or five other individuals of each species.

We followed Maina's methodology (Maina,2002) to fixate lung tissues. We used sections of each lobule of both lungs to prepare 4–10 blocks, from which small pieces (1–2 mm thick) were obtained. These samples were fixed in glutaraldehyde (2.3%glutaraldehyde in phosphate buffer) for 2 h at 4°C, washed in buffer and postfixed with 1% osmium tetroxide, and then dehydrated in gradually increasing concentrations of ethanol. Semithin sections (1 μm thick) were prepared and stained with 1% Toluidine Blue. Ultrathin sections (60–90 nm) were prepared and contrasted with lead citrate before examination by transmission electron microscopy (JEOL/JEM 100SX, Musashino, Tokyo, Japan)

The images were digitalized and studied using SCION IMAGE software(Frederick, MD, USA). The harmonic mean thickness of the blood–gas barrier (τh) was estimated by means of point-and-line counting in a grid, as suggested by Weibel(1970/71) and Maina(2002). Twelve measurements ofτ h in different parts of the lungs were obtained for each individual and the species effect on τh was analyzed by repeated-measures ANOVA. Alveolar surface density was estimated by measuring directly the alveolar perimeter in three fields of each lung section per individual in the optical microscope. We considered the ratio of alveolar perimeter to field area (R) as a good estimator of the alveolar surface density, following the principle of stereological methodology(Weibel, 1970/71; Weibel at al., 1981). Lung volume was estimated from radiographs of four individuals of T. brasiliensis (Mb=11.95±1.4 g), four individuals of A. olivaceus (Mb=26.0±4.3 g) and five individuals of A. andinus(Mb=25.4±3.0 g). On lung images, we traced a straight line (RL) between the costophrenic recesses, and measured: (i) the width of RL (W) as a lateral measurement; (ii) the height between RL and the top of the left (H1) and the right(H2) lung; and (iii) left (w1) and right (w2) lung width at the middle point of diaphragm domes. Recently, Canals et al.(2005b), showed that LV*=0.496VRX≈1/2VRX is a good estimator of lung volume in small mammals, where VRX=W[(H1+H2)/2]×[(w1+w2)/2]represents the volume of a box containing the lungs. The parenchymal lung volume was estimated as LVp=0.9LV* (Maina, 2000a,b). From these structural measurements the morphometric oxygen diffusion capacity was estimated using: DtO2=κ(Dsa×LVp)/τh,where DtO2 is the oxygen diffusion capacity of the blood–gas barrier (tissue), κ is the Krogh's diffusion coefficientκ=4.1×10–8 cm2 s–1Pa–1 (Maina,2002) and Dsa is the alveolar surface density.

Airway geometry

We initially dealt with all individuals of each species. Animals were euthanized and bronchographs were immediately performed, using an 18 g plastic catheter introduced into the trachea. Water-diluted barium sulfate was introduced into the airway followed by air, to displace the contrast medium filling to the thinnest bronchi. The procedure was performed using radioscopic visualization in the X-ray service of a public hospital in Chile (Hospital Del Salvador). Radiographs were taken at a distance of 1 m, at 100 mA, 0.04 s and between 24 and 34 kV. Bronchographs were digitalized in a standard format of 400 pixels from the clavicle plane to the distal bronchi. Bronchi order was assigned using Horsfield's system(Horsfield, 1990), which assigns bronchial order from distal to proximal zones. The distal (fine)airway has smaller order values than proximal ones. A bronchograph was considered sufficient whenever more than 12 relative orders were recognized. The fractal dimensions of the bronchial images were computed by means of the box-counting method, implemented using BENOIT software (St Petersburg, FL,USA). We analyzed 15, 7 and 16 individuals of A. olivaceus, A. andinus and T. brasiliensis, respectively. Comparisons between the species were analyzed using a one-way ANOVA with Tukey multiple comparisons.

We selected the best radiographs for subsequent analyses, retaining only those in which the bronchial junctions were clearly recognizable. We classified a junction as distal if the relative Horstfield order of the thinnest bifurcation branch was lower than 3 and as proximal if its order was larger than 5. Three proximal and three distal junctions were selected to study the departures from optimality. To avoid underestimation due to rotations, the junctions selected from a particular level were those that did not overlap and had the largest bifurcation angle. Only 3, 2 and 4 individuals of A. olivaceus, A. andinus and T. brasiliensis satisfied these restrictive criteria and were therefore analyzed. The diameter, length and bifurcation angles (θ) of the parent and daughter branches of each bifurcation were measured from digitized images (Figs 1 and 2). The length and diameter scaling ratios (γ and γd) were estimated by dividing the average diameter of the daughter branches by that of the parent branch. Also, a diameter and length symmetry ratio (Dr and Lr, respectively) between the daughter branches were computed, always using the lower value in the numerator of the ratio, so that Dr and Lr ≤1.

Recently Canals et al.(2004) proposed thatθ=60° and

\({\gamma}=\sqrt[3]{(1{/}2)}=0.7937\)
should be expected for a geometrically optimized bronchial tree. From a physical perspective, in a symmetric bifurcation with laminar flow, θ=74.934°and
\({\gamma}_{\mathrm{d}}=\sqrt[3]{(1{/}2)}=0.7937\)
is expected on the basis of minimum energy loss, minimum volume and pumping power principles (Kamiya et al.,1974; Zamir and Bigelow,1984; Mauroy et al.,2004). Considering these bases, Canals et al.(2004) defined estimators of the physical and geometrical distances to the expected optima for each junction in the following way: X, Y and Z coordinates as X=sin(θ/2) for both the physical and geometrical domains, Y=γ for the geometrical and Yd for the physical domains; and finally Z=Lr for the geometrical and Z=Dr for the physical domain, the latter estimating the symmetry of the bifurcation. With these definitions these authors expected a geometric optimum point (X0, Y0, Z0)=(sin30°, 0.7937, 1)=(0.5,0.7937, 1) and a physical optimum point (X0, Y0, Z0)=(sin 37.467°, 0.7937,1)=(0.6083, 0.7937, 1); then by defining the departures from the optima as dX=XX0,dY=YY0,dZ=ZZ0 they proposed geometrical(dG) and physical (dp) distances to the optima as Euclidean distances in each domain as:
\(\sqrt{(\mathrm{d}X^{2}+\mathrm{d}Y^{2}+\mathrm{d}Z^{2})}\)
(Fig. 1).

The pair D=(dG,dp) was first considered as a single vector, and the species effect on that pair was analyzed by repeated-measures MANOVA. Then dG, dp, the bifurcation angle θ, the daughter–parent length (γ) and diameter (γd)scaling ratios, as well as the symmetry ratios Dr and Lr, were analyzed using repeated-measures two-way ANOVA with SNK multiple comparisons.

Functional parameters

The RMR of Tadarida brasiliensis was lower than that of both Abrothrix species (F2,60=33.2, P≪0.01) whereas its maximum metabolic rate(O2max) was higher (F2,60=17.3, P≪0.01). Therefore Tadarida brasiliensis had a larger metabolic scope than the rodents(Table 1).

Structural lung parameters

The blood–gas barrier of Tadarida brasiliensis (Tb)was thinner than that of both A. olivaceus (Ao) and A. andinus (Aa) (F2,6=4.91, P=0.05; Tb–Ao, P=0.044; Tb–Aa, P=0.028 and AoAa, P=0.75 in Tukey multiple comparisons; Figs 3, 4, 5). The alveolar surface density of the bat was not significantly different than those of the rodents(P>0.05), but T. brasiliensis had a larger relative lung volume than rodents: 0.055±0.011 ml g–1,0.043±0.010 ml g–1 and 0.036±0.006 ml g–1 for T. brasiliensis, A. andinus and A. olivaceus, respectively (F2,10=5.18, P=0.029). The mass-specific alveolar surface was also higher in the bat (Table 2).

Geometrical and physical optimization of the airway

Comparing the airway radiographs of the three species, we found that all of them fill the lung's space to a similar extent. The fractal dimensions of the species were: A. olivaceus, 1.703±0.021; A. andinus,1.670±0.012; and T. brasiliensis, 1.682±0.012(F2,28=0.734; P>0.05). These were slightly higher than the values of 1.57 for Rattus norvegicus, 1.57–1.62 for Oryctolagus cuniculus and 1.57 for Homo sapiens,obtained using a somewhat different methodology by Canals et al.(1998).

The distances to the geometric and physical optima of the bronchial junctions decreased from the proximal zone to the distal zone[F1,8=26.7, P≪0.01 for the geometrical distance; F1,8=58.69, P≪0.01 for the physical distance; and F2,7=10.69, P<0.01 for the vector D=(dG,dp) in the repeated-measures MANOVA]. We did not find interspecific effects in scalar or vector distances in the studied species [F2,8=1.1, P=0.378; F2,8=1.97, P=0.211 and F4,14=2.49, P=0.09 for dG, dp and the vector D=(dG,dp) respectively; Table 3]. However, we found a significant interaction between species and zone factors on the physical distance (F2,8=17.47, P≪0.01). This interaction was the result of a smaller physical distance in the bat than in the rodents in the proximal zone. In contrast, in the distal zone, the distances of all species were very similar(Fig. 6).

Geometrical distances depend on the bifurcation angle θ, the ratio between the length of the daughter and the parent branches (γ) and on the ratio between the lengths of daughter branches (Lr). Physical distances are determined by the bifurcation angle θ, the ratio between the diameter of the daughter and the parent branches(γd) and the ratio between the diameters of the daughter branches (Dr). When we explored the behavior of these components of both distances we did not find interspecific differences(F2,14=0.21, P>0.05), but the bifurcation angle increased from proximal to distal zone (F1,14=16.13, P≪0.01; Table 4). Neither of the geometrical components γ and Lrdiffered among species (F2,8=0.99 and F2,8=0.49, P>0.05 for γ and Lr, respectively) but both increased from proximal to distal zones (F1,8=9.3, P<0.05 and F1,8=15.0, P<0.01) (Tables 5 and 6).

The physical components γd and Dr were similar among species (F2,8=1.12 and F2,8=1.57, P>0.05 for γd and Dr, respectively), but both increased from proximal to distal zones (F2,8=4.2, P<0.05 and F2,8=23.6, P<0.01). Furthermore, Dr showed a species×zone interaction effect due to larger Dr values in the proximal zone of T. brasiliensis (F2,8=7.25, P<0.05). Although a similar pattern could be observed for γp, the species–zone interaction was not significant(Fig. 7).

Functional parameters

The O2max of T. brasiliensis was in the same range as those of small insectivores(see Sparti, 1992) and similar to that of Glossophagine bats (Mb=7–28 g) during short hovering events, which ranges from 20.5 ml O g–1h–1 to 27.3 ml O2 g–1h–1 (Winter et al.,1998; Voigt and Winter,1999). The O2max of T. brasiliensis was lower than that expected from the allometric relationship O2=186.91Mb–0.3 (Mb in kg and O2max in ml O2 min–1 kg–1) proposed by Thomas(1987; 43.1 ml O2g–1 h–1), but is 179.3% of the value predicted by the allometric relationship O2max=28.05Mb–0.337(Mb in g and O2max in ml O2g–1 h–1) for rodents(Rezende et al., 2004). Thomas(1987) estimated that metabolic rates of flying mammals are twice as high as those of running mammals. However, our data agree with Harrison and Roberts(2000), who suggested that small bats have aerobic capacities that are only about 50% higher than those of running mammals.

Structural lung parameters

The mass-specific alveolar surface was similar to that of several bats such as Phyllostomus hastatus (37.2 cm2 g–1), Cheiromeles torquatus (33.3 cm2 g–1) and Cynopterus brachyotes (30.0 cm2 g–1; Maina et al., 1991), but lower than in other small bat species whose mass-specific alveolar surfaces ranged from 50–63.2 cm2 g–1 (Maina et al., 1991, 2000a,b).

The harmonic mean thickness of the tissue barrier was 0.230 μm, similar to those of other bats, which range from 0.1204 μm in Phyllostomus hastatus to 0.3033 in Pteropus poliocephalus(Maina and King, 1984). The estimated mass-specific diffusion capacity (tissue), DtO2,of T.brasiliensis, 6.98×10–6 ml O2 s–1 Pa–1 g–1,is within the range 1.07×10–6–23.4×10–6 ml O2 s–1 Pa–1 g–1reported for bats weighing between 5.1 g and 456.03 g(Maina and King, 1984; Maina et al., 1991).

Tadarida brasiliensis showed a mass-specific DtO2 from 2–3 times higher than those of the studied rodents. From data of Maina et al.(1991) and Maina(2000b), we observed that DLO2 is about 1/10 of DtO2(DLO2/DtO2 ratio=0.092±0.070 in birds and 0.100±0.031 in bats). Assuming this value, we may compare our rodent data with those of Gehr et al.(1981) for several mammals. Our rodents had a mass-specific DtO2 that was slightly lower than those estimated for Mus musculus (42 g;5.07×10–6 ml O2 s–1Pa–1 g–1), Mus wagneri (13 g;7.46×10–6 ml O2 s–1Pa–1 g–1) and Rattus rattus (140 g;4.85×10–6 ml O2 s–1Pa–1 g–1). Both maximum metabolic rates and the structurally derived DtO2 showed an increase from low values in A. olivaceus, medium values in A. andinus to high values in the bat T. brasiliensis. This may be correlated with the energetic requirements of the habitats and life styles of these species. A. olivaceus inhabits grasslands, bushes, open forests and stony areas from sea level up to 2500 masl, while A. andinus usually dwells in high-Andean zones between 3500 and 4600 masl. T. brasiliensis is a flying mammal that usually flies long distances and at high altitude(Gantz and Martinez, 2000; Kunz and Fenton, 2003).

Geometrical and physical optimization of the airway

Breathing work depends on the resistance of all components of the respiratory systems to respiratory movements and airflow. Among them, the main component of the total respiratory resistance is the resistance generated within the airway (80% in humans). This resistance is generated primarily in the proximal airway because of its reduced sectional area relative to that of the distal airways. For example, in humans the airways with bronchial diameters less than 2 mm are only responsible for 20% of the airway resistance. Thus, the geometry of the proximal airway is a key factor in determining the work needed for breathing. Another relevant factor is breathing frequency. The increments of breathing frequency are paralleled by a decrease in elastic work, but mainly by increments in the work to overcome the turbulent flow (turbulent work) and the viscous resistance (viscous work) that lead an increased total work (West,2000).

Geometrically, the airways of the studied species approached the optimum from proximal to distal, sacrificing the angle, but varying the symmetry and improving γ. From a physical perspective, the optimum was approached from proximal to distal, improving the symmetry, bifurcation angle and the scaling ratio, γd. However, the airway of bats departed from this pattern, maintaining a better γd in the proximal zone. In a previous report, Canals et al.(2004) found a decrease in both geometrical and physical distances to the optimum from proximal to distal zones in the airway of several mammals. The reported distances for rabbits and rats are in the range of the reported values in the present study. For example, average values in Oryctolagus cuniculus and Rattus norvegicus were dp=0.374 and dp=0.417, respectively.

In T. brasiliensis a decrease was evident in the geometrical distance but not in the physical distance. This latter was always close to the physical optimum. The diameter ratio, γd, was close to, but lower than the expected

\({\gamma}=\sqrt[3]{(1{/}2)}=0.7937\)
in both proximal and distal zones. The bifurcation angle, however, varied from 52.2° to 70.9° from proximal to distal airway zones, respectively. The first value was near the geometrical optimum angle (60°). This could be associated with ascendancy of geometrical principles in the distribution of the proximal airway, which could be related to the need to increase the branches to fill a space and with the higher flow velocities in the proximal zone associated with high breathing rate. These imply high Reynold's numbers and increased energetic costs by increased viscous work and turbulence flow(Massaro and Massaro, 2002). If that is the case, a lower physical optimum angle is expected(Kamiya et al., 1974) because it reduces the probability of turbulent flow. This is possible even in fully symmetric trees with more than three bifurcation generations(Andrade et al., 1998). The energetic saving for the bat may be relevant because better optimization values occur in the proximal zone of the airway where the main proportion of the resistance to air flow is generated. Furthermore, bats can reach very high breathing frequencies and tidal volumes during flight(Thomas, 1987). These increase both the turbulent and viscous respiratory work and making energetic saving important.

In the studied species, the average diameter scaling ratio in the distal zones ranged from 0.716 to 0.752. This feature may be critical because in symmetrical bronchial trees the flow resistance is highly sensitive toγ d (Mauroy et al.,2004): low γd implies high resistance. One explanation for this feature is that the exponent `n=3' in Murray's law used in the derivation of airway models that predict an optimalγ d=0.7937, may be lower than that for transitional or turbulent air flow, conditioning both a lower bifurcation angle and a lowerγ d. For example n-exponents have been reported from 2.4 to 2.9 for the airways of four mammals(Horsfield and Thurlbeck,1981), and 2.8 for the human airway(Kitaota and Suki, 1997). Furthermore, the airways of most mammals are asymmetrical(Canals et al., 2002b). On average, the symmetry ratios of the studied species varied from 0.688 in the proximal zone to 0.798 in the distal zone. This feature could contribute towards decreasing the expected γd optimum, and consequently to reducing the dead space, thus requiring a lower tidal volume(Mauroy et al., 2004).

Tadarida brasiliensis showed evidence of the importance of the interaction between the diameter asymmetry of the bronchial tree, the diameter scaling ratio (γd) and the distance to the physical optimum in the proximal airway zone. This species showed the lowest distance, which was sustained by a better symmetry (larger Dr) and was accompanied by a scaling ratio closer to the optimum. These findings agree with the predictions of Mauroy et al.(2004), who estimated that a 4% of decrease in γd would nearly double the bronchial tree resistance, decreasing the air flow by 50%.

In brief, T. brasiliensis showed a high aerobic capacity that was sustained by modifications of both lungs and airways. The bats show reductions in the thickness of the blood–gas barrier, and modifications in lung volume and the geometry of the bronchial tree, but no modifications in the general design of the mammalian respiratory system. It showed the best physical optimization values in the proximal zone. This may be an important feature that saves energy and minimizes energy loss during breathing. Those features, together with previously reported optimization of cardiovascular parameters, such as the haematocryt, red blood cell number, heart mass and heart rate (Maina, 1998),probably facilitate satisfying the high energetic demands of flight in bats.

     
  • dG

    geometrical distance to the optimum value

  •  
  • D=(dg,dp)

    vector of distances

  •  
  • DLO2

    mass-specific diffusion capacity (total, including plasma and red cells)

  •  
  • dp

    physical distance to the optimum value

  •  
  • Dr

    diameter symmetry ratio (daughter:parent)

  •  
  • Dsa

    alveolar surface density

  •  
  • DtO2

    morphometric oxygen diffusion capacity (tissue)

  •  
  • Lr

    length symmetry ratio (daughters)

  •  
  • LV*

    lung volume estimator

  •  
  • LVp

    parenchymal lung volume

  •  
  • Mb

    body mass

  •  
  • MS

    metabolic scope

  •  
  • RMR

    resting metabolic rate

  •  
  • R

    ratio of alveolar perimeter to field area

  •  
  • O2

    oxygen consumption

  •  
  • O2max

    maximum oxygen consumption

  •  
  • VRX

    volume of a box containing the lungs

  •  
  • γ

    length scaling ratio

  •  
  • γ*

    optimum scaling ratio

  •  
  • γd

    diameter scaling ratio

  •  
  • κ

    Krogh's diffusion factor

  •  
  • θ

    bronchial bifurcation angle

  •  
  • τh

    harmonic mean thickness of the blood gas barrier

This work was supported by the FONDECYT 1040649 grant to M.C.L. We thank Dr Carlos Martinez and Dr Lafayette Eaton for improving the English.

Andrade, J. S., Alencar, A. M., Almeida, M. P., Mendes Filho,J., Buldyrev, S. V., Zapperi, S., Stanley, H. E. and Suki, B.(
1998
). Asymmetric flow in symmetric branched structures.
Phys. Rev. Lett.
81
,
926
-929.
Bartholomew, G. A., Leitner, P. and Nelson, J. E.(
1964
). Body temperature, oxygen consumption and heart rate in three species of Australian flying foxes.
Physiol. Zool.
37
,
179
-198.
Canals, M., Olivares, R., Labra, F., Caputo, L., Rivera, A. and Novoa, F. F. (
1998
). Caracterización de la geometría fractal del arbol bronquial en mamiferos.
Rev. Chil. Anat.
16
,
237
-244.
Canals, M., Atala, C., Olivares, R., Novoa, F. F. and Rosenmann,M. (
2002a
). Departures from the physical otimality in the bronchial tree of rats (Rattus norvegicus).
Biol. Res.
35
,
411
-419.
Canals, M., Atala, C., Olivares, R., Novoa, F. F. and Rosenmann,M. (
2002b
). La asimetría y el grado de optimización del árbol bronquial en Rattus norvegicusand Oryctolagus cuniculus.
Rev. Chil. Hist. Nat.
75
,
271
-282.
Canals, M., Iriarte-Díaz, J., Olivares, R. and Novoa, F. F. (
2002c
). Comparación de la morfología alar de Tadarida brasiliensis (Chiroptera: Molossidae) y Myotis chiloensis (Chiroptera: Vespertilionidae), representantes de dos patrones de vuelo.
Rev. Chil. Hist. Nat.
74
,
699
-704.
Canals, M., Novoa, F. F. and Rosenmann, M.(
2004
). A simple geometrical pattern for the branching distribution of the bronchial tree, useful to estimate optimality departures.
Acta Biotheoretica
52
,
1
-16.
Canals, M., Atala, C., Grossi, B. and Iriarte-Díaz,J. (
2005a
). Heart and lung size of several small bats.
Acta Chiropt.
7
,
65
-72.
Canals, M., Olivares, R. and Rosenmann, M.(
2005b
). Estimating the lung volume of small rodents from radiographs.
Biol. Res.
38
,
41
-47.
Gantz, A. P. and Martinez, D. R. (
2000
). Chiroptera. In
Mamíferos de Chile
(ed. A. P. Muñoz and J. V. Yañez), pp.
53
-66. Santiago: CEA Ediciones
Gehr, P., Mwangi, D. K., Ammann, A., Maloiy, G. M. O., Taylor,C. R. and Weibel, E. R. (
1981
). Design of the mammalian respiratory system. V. Scaling morphometric pulmonary diffusing capacity to body mass: wild and domestic mammals.
Respir. Physiol.
44
,
61
-86.
Greenewalt, C. H. (
1975
). The flight of birds:the significant dimensions, their departure from the requirements for dimensional similarity and the effect on flight aerodynamics of that departure.
Trans. Am. Phil. Soc.
65
,
1
-67.
Harrison, J. F. and Roberts, S. P. (
2000
). Flight respiration and energetics.
Annu. Rev. Physiol.
2000
,
179
-205.
Horsfield, K. (
1990
). Diameters, generations and orders of branches in the bronchial tree.
J. Appl. Physiol.
68
,
457
-461.
Horsfield, K. and Thurlbeck, A. (
1981
). Relation between diameter and flow in branches of the bronchial tree.
Bull. Math. Biol.
43
,
681
-691.
Iriarte-Díaz, J., Novoa, F. F. and Canals, M.(
2002
). Biomechanic consequences of differences in wing morphology between Tadarida brasiliensis and Myotis chiloensis.
Acta Theriol.
47
,
193
-200.
Johansen, K., Berger, M., Bicudo, J. E. P. W., Ruschi, A. and de Almeida, P. J. (
1987
). Respiratory properties of blood and myoglobin in hummingbirds.
Physiol. Zool.
60
,
269
-278.
Jürgens, J. D., Bartels, H. and Bartels, R.(
1981
). Blood oxygen transport and organ weight of small bats and small non-flying mammals.
Respir. Physiol.
45
,
243
-260.
Kamiya, A., Togawa, T. and Yamamoto, A. (
1974
). Theoretical relationships between the optimal models of the vascular tree.
Bull. Math. Biol.
36
,
311
-323.
Kitaota, H. and Suki, B. (
1997
). Branching design of the bronchial tree based on a diameter-flow relationship.
J. Appl. Physiol.
82
,
968
-976.
Kunz, T. H. and Fenton, M. B. (
2003
).
Bat Ecology
. Chicago and London: The University of Chicago Press.
Lechner, A. J. (
1985
). Pulmonary design in a microchiropteran bat (Pipistrellus subflavus) during hibernation.
Respir. Physiol.
59
,
301
-312.
Maina, J. N. (
1998
). The lungs of the flying vertebrates – birds and bats: is their structure optimized for this elite mode of locomotion? In
Principles of Animal Design: The Optimization and Symmorphosis Debate
(ed. E. R. Weibel, C. R. Taylor and L. Bolis), pp.
177
-185. Cambridge:Cambridge University Press.
Maina, J. N. (
2000a
). What it takes to fly: the structural and functional respiratory refinements in birds and bats.
J. Exp. Biol.
203
,
3045
-3064.
Maina, J. N. (
2000b
). Comparative respiratory morphology: Themes and principles in the design and construction of the gas exchangers.
Anat. Rec.
261
,
25
-44.
Maina, J. N. (
2002
). Some recent advances on the study and understanding of the functional design of the avian lung:morphological and morphometric perspectives.
Biol. Rev.
77
,
97
-152.
Maina, J. N. and King, A. S. (
1984
). The structural functional correlation in the design of the bat lung. A morphometric study.
J. Exp. Biol.
111
,
43
-63.
Maina, J. N., Thomas, S. P. and Dalls, D. M.(
1991
). A morphometric study of bats of different size:correlations between structure and function of the chiropteran lung.
Phil. Trans. R. Soc. Lond. B
333
,
31
-50.
Mann, G. (
1978
). Los pequeños mamíferos de Chile: marsupials, quirópteros, edentados y roedores.
Gayana Zool.
40
,
9
-342.
Massaro, D. and Massaro, G. D. (
2002
). Pulmonary alveoli: formation, the `call of oxygen', and other regulators.
Am. J. Physiol.
282
,
L345
-L358.
Mathieu-Costello, O., Szewcsak, J. M., Logerman, R. B. and Agey,P. J. (
1992
). Geometry of blood–tissue exchange in bat flight muscle compared with bat hindlimb and rat soleus muscle.
Am. J. Physiol.
262
,
955
-965.
Mauroy, B., Filoche, M., Weibel, E. R. and Sapoval, B.(
2004
). An optimal brobchial tree may be dangerous.
Nature
427
,
633
-636.
Murray, C. D. (
1926
). The physiological principle of minimum work.
Proc. Natl. Acad. Sci. USA
12
,
207
-214.
Rezende, E. L., Bozinovic, F. and Garland, T., Jr(
2004
). Climatic adaptation and the evolution of basal and maximum rates of metabolism in rodents.
Evolution
58
,
1361
-1374.
Rohrer, F. (
1915
). Flow resistance in human air passages and the effect of irregular branching of the bronchial system on the respiratory process in various regions of the lungs.
Pflügers Arch.
162
,
255
-299.
Rosenmann, M. and Morrison, P. R. (
1974
). Maximum oxygen consumption and heat loss facilitation in small homeotherms by He-O2.
Am. J. Physiol.
226
,
490
-495.
Schmidt-Nielsen, K. (
1997
).
Animal Physiology. Adaptation and environment
. Cambridge: Cambridge University Press.
Sparti, A. (
1992
). Thermogenic capacity of shrews (Mammalia, Soricidae) and its relationship with basal rate of metabolism.
Physiol. Zool.
65
,
77
-96.
Thomas, S. P. (
1987
). The physiology of bat flight. In
Recent Advances in the Study of Bats
(ed. M. B. Fenton, P. Racey and J. M. V. Rayner), pp.
75
-99. Cambridge: Cambridge University Press.
Thomas, S. P., Lust, M. R. and van Riper, H. J.(
1984
). Ventilation and oxygen extraction in the bat Phyllostomus hastatus during rest and steady flight.
Physiol. Zool.
57
,
237
-250.
Voigt, C. C. and Winter, W. (
1999
). Energetic cost of hovering flight in nectar feeding bats (Phyllostomidae:Glossophaginae) and its scaling in moths, birds and bats.
J. Comp. Physiol. B
169
,
38
-48.
Weibel, E. R. (
1970/71
). Morphometric estimation of pulmonary diffusion capacity.
Respir. Physiol.
11
,
54
-75.
Weibel, E. R. (
1998
). Introduction. In
Principles of Animal Design. The Optimization and Symmorphosis Debate
(ed. E. R. Weibel, C. R. Taylor and L. Bolis), pp.
1
-11. Cambridge: Cambridge University Press.
Weibel, E. R. and Gomez, D. M. (
1962
). Architecture of the human lung.
Science
137
,
577
-585.
Weibel, E. R., Gehr, P., Cruz-Ori, L., Muller, A. E., Mwangi, D. K. and Haussener, V. (
1981
). Design of the mammalian respiration system. IV. Morphometric estimation of pulmonary diffusing capacity: critical evaluation of a new sampling method.
Respir. Physiol.
44
,
39
-59.
West, J. B. (
2000
).
Respiratory Physiology – The Essentials
. 6th edn. Baltimore:Williams and Wilkins.
Winter, Y., Voigt, C. and Von Helversen, O.(
1998
). Gas exchange during hovering flight in a nectar-feeding bat Glossophaga soricina.
J. Exp. Biol.
201
,
237
-244.
Wolk, E. and Bogdanowics, W. (
1987
). Hematology of the hibernating bat, Myotis daubentoni.
Comp. Biochem. Physiol.
88A
,
637
-639.
Zamir, M. and Bigelow, D. C. (
1984
). Cost of departure from optimality in arterial branching.
J. Theor. Biol.
109
,
401
-409.